AUG/18/56 Oaks Farm Bulmer Lane Holme on Spalding Moor East Yorkshire YO43 4HE #11864 · AUG/18/56

Status: won   Value: £790.00

Address: Holme on Spalding Moor, YO43 4HE, United Kingdom   View on map ↗

Company: Mr Robert Templey

Brief:

Conversion of Existing Barn to Form Holiday Letting Unit
Notes
32
Tasks
11
Invoices
0
Contracts
0
Inspections
0

Notes + New note

Completion Cert - 22/04/21
enquiry 2021-04-22 14:13:12
Follow Up: final cert please
enquiry 2021-04-22 14:13:05
phone call from client confirms that restrictor fitted to the window as requested agreed to issue final cert jab
enquiry 2021-04-22 09:08:58
Final Inspection letter - 21/04/21
enquiry 2021-04-21 10:34:14
Follow Up: final inspection letter please
enquiry 2021-04-21 10:34:06
Final Inspection Letter - 21/04/21
enquiry 2021-04-21 10:33:39
Site Inspection: site visit
enquiry 2021-03-18 11:35:52
RETIREMENT LETTER SENT
enquiry 2021-03-04 14:21:15
rang client complete other than certificar]tion for gas electric and EPC will forward when got and we will arrange a final inspectio0n jab
enquiry 2021-01-28 12:36:46
clients number 07816546109
enquiry 2021-01-28 12:33:45
rang client requested update on progress left message to call me back asap jab
enquiry 2021-01-28 11:46:18
file audit phone call to client says will contac t office when all works complete jab
enquiry 2020-06-17 10:36:36
Site Inspection: HOLME ON SPALDING - pre plaster 07725 138470
enquiry 2019-12-02 10:38:20
contact 2019-04-24 11:47:56
01132562295 ella wright
contact 2019-04-24 11:47:55
Follow Up: Photos and roof
enquiry 2019-03-13 11:03:37
Calcs added to file.
enquiry 2019-03-11 13:47:04
Site Inspection: HOLME ON SPALDING MOOR - roof
enquiry 2019-03-11 13:11:53
Follow Up: Floor and roof
enquiry 2019-01-17 10:29:59
Site Inspection: HOSM OVERSITE ian 07725138470
enquiry 2019-01-16 14:52:53
Site Inspection: trial holes 07725138470 ring half hour before
enquiry 2018-10-02 11:49:26
Site Inspection: HOLME ON SPALDING MOOR - AM if possible commencement
enquiry 2018-10-01 11:27:17
Call: what stastarting tueday ge do we need to look asked him to ring you as well
enquiry 2018-09-28 09:37:47
Drainage letter - Acceptable
24.09.18
enquiry 2018-09-25 09:48:08
james templey 07725138470
enquiry 2018-09-21 14:45:47
Hi Robert and James

The attached are;

• Plasmor SAP Specification and reports
• Dwg 700/100A Building Regulations notes

I refer you to the SAP Specification final entry. SAP result – PASS – Elemental U Value Pass required only

Leanne has prepared the SAP specification and reports using her own U value calculations. I am aware their accreditation system requires SAP Assessors to undertake their own calculations and essentially, not believe those supplied to them! It’s a good job as the British Gypsum ones that I obtained via the British Gypsum website calculator were slightly over specifying. The thickness of Thermaline has reduced from 80mm to 70mm. Consequently, my Regs notes have been revised accordingly.

The email trail below is between Leanne and me to finalise the various elements for the SAP. One matter is the ceiling above the living room area. The SAP is resolved to raise the flat roof ceiling area to nom 2750mm. This introduces a small area of sloping (raking) ceiling, which is included in the SAP and Regs notes.

I trust this is acceptable to you both.

Cheers

Steve

Steve Jenneson

Jenneson Associates Ltd
enquiry 2018-09-12 19:46:12
sap reports
enquiry 2018-09-12 19:45:48
Please find attached dwg 700/100 Building Regulations specification notes, together with three British Gypsum U value calculations and specifications.

I’ve included an lpg boiler for heating the barn conversion. I do recall you saying that you may consider an air source heat pump. But, I had to gamble and the lpg boiler is the worse of the two for SAP compliance. In other words, if you do use the air source heat pump then the SAP will improve.

Ii is perhaps worth saying that you require both SAP and EPC for Building Control but they don’t actually need to show a pass, as this is conversion. The primary driver is compliance with the U values stated in the Regs and used in this specification.

I trust this assists all of you.

Cheers

Steve

Steve Jenneson

Jenneson Associates Ltd

Business office - May Cottage, Mill Lane, Seaton Ross, York, YO42 4NE. Tel No 01759 318200. Fax No 01759 318210. www.jennesonassociates.co.uk
enquiry 2018-09-06 18:17:18
Cheque received £948
enquiry 2018-08-28 14:49:44
IN Acceptance - 21/08/18
enquiry 2018-08-21 16:44:42
The project was marked as 'Won'
enquiry 2018-08-21 09:18:47
The project was created
enquiry 2018-08-21 09:18:35

Tasks

final cert please
Due 2021-04-22 00:00:00 · high · Follow Up
final inspection letter please
Due 2021-04-20 00:00:00 · high · Follow Up
site visit
Due 2021-03-17 00:00:00 · · Site Inspection
HOLME ON SPALDING - pre plaster 07725 138470
Due 2019-12-02 00:00:00 · · Site Inspection
Photos and roof
Due 2019-03-12 00:00:00 · · Follow Up
HOLME ON SPALDING MOOR - roof
Due 2019-03-11 00:00:00 · · Site Inspection
Floor and roof
Due 2019-01-17 00:00:00 · · Follow Up
HOSM OVERSITE ian 07725138470
Due 2019-01-16 00:00:00 · · Site Inspection
trial holes 07725138470 ring half hour before
Due 2018-10-02 00:00:00 · · Site Inspection
HOLME ON SPALDING MOOR - AM if possible commencement
Due 2018-10-01 00:00:00 · · Site Inspection
what stastarting tueday ge do we need to look asked him to ring you as well
Due 2018-09-25 00:00:00 · · Call